logo
Service Hotline:
+86-371-22321060
Hotline: +86-
371-22321060
W-M3000J Wafer type electromagnetic flowmeter
\

I.Feature
1.Self-diagnosis
2.Power failure record
3.Alarm(Empty,excitation,high&low etc.)
4.Lightning proof
5.Language and colors can be customized
 
II.Technical parameter
DN size(mm): From DN10 to DN200(2/5" to 8") Measuring range: 0 to 10 m/s
Accuracy: ±0.5%FS(±0.2%,±0.3% optional)
Measuring medium: Liquid or solid-liquid phase medium with a conductivity higher than 5μs/cm. 
 
Operating pressure: Max. 25 bar (Max. 360 psi)
Ambient temperature: From -20 to 60 °C (-4 to 140 °F)
Medium temperature: From -20 to 150 °C (-4 to 300 °F) F46,
PTFE,
 
Liner:
 
PFA,
Electrode:
 
SS316
Hastelloy B Hastelloy C Titanium Tantalum Pltinum-iridium Tungsten carbide
 
 
 
Material: Carbon steel/SS304/SS316
Enclosure sensor:
 
Signal output: 4~20mA and pulse.
 
Communications: RS485, Modbus, RS232, HART, Profibus, GPRS, etc. Transmitter: Large LCD 
 
with backlight
Cable: Compact type no need; remote type Default 10m
Earth ring: SS316 (Optional) Standard DIN,ANSI,JIS
 
 
 
III.Flow